Crysalli Beverage Dispense Systems Components

POST MIX TOWERS

CM-T-4V-PBV CM-T-6V-PBV CM-T-8V-PBV

Specifications

  • Blue LED illuminated push and hold to dispense buttons
  • Integrated base & drip pan
  • Valves can be configured for carbonated or non-carbonated beverages
  • 304 stainless steel brushed finish
  • Key to lock out dispense buttons
  • Faucet flow rate: 1.5-2.0 oz/sec
  • Clearance: 10″
  • 20″W x 12″D x 17.375″ H
  • 120V – 1 Amp – 60 Hz
  • Dispense tower to be paired with the CBDS cold carb or non-carb remote chiller

  Spec Sheet (556 KB)

COLD CARB CHILLERS

CBDS-P2000-R-UC

Remote Beverage Chiller

Fountain Dispense Cold Carb Chiller

  • Undercounter recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean, stainless steel cabinet
  • 304 stainless steel brushed finish panels
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 1, 12 oz drink per minute (Max capacity: 50, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <40°F
  • Self-contained refrigeration system
  • Compressor: 1/9 H.P.
  • Refrigerant: R134a CFC-free
  • Electrical: 120 VAC
  • Minimum amps: 4.5
  • Cold carbonation technology
  • Carbonator pump: 1 GPM (max pressure 160 PSI)
  • Built-in re-circulatory pump allows for an installation distance up to 6’ between chiller and dispenser
  • Water Bath: 2.5 Gallons
  • Ice Bank: 6 lbs
  • Dry Weight: 80 lbs
  • 11.75”W x 17.5”D x 16.5”H
  • CBDS-P2000-R-UC-BH-R4 and R-6 are reverse osmosis compatible

Spec Sheet (674 KB)

CBDS-UCM1

Remote Beverage Chiller

Fountain Dispense Cold Carb Chiller

  • Remote recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean stainless steel cabinet
  • 304 stainless steel brushed finish panels
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 2, 12 oz drinks per minute (Max capacity: 80, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <40°F
  • Self-contained refrigeration system
  • Compressor: 1/5 H.P.
  • Refrigerant: R134a CFC-free
  • BTU: 2,2000 per hour average
  • Electrical: 120 VAC
  • Minimum amps: 9.6
  • Cold carbonation technology
  • Carbonator: 1.67 GPM (100 GPH)
  • Water Bath: 4 Gallons
  • Ice Bank: 9.5 lbs
  • Weight: 115 lbs
  • Built-in re-circulatory pump allows for an installation distance up to 35’ between tower and chiller
  • 12”W x 23.5”D x 24.5”H

Spec Sheet (718 KB)

CBDS-UCM2-2CL

Remote Beverage Chiller

Fountain Dispense Cold Carb Chiller

  • Remote recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser(s)
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean stainless steel cabinet
  • 304 stainless steel brushed finish panels
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 3, 12 oz drinks per minute (Max capacity: 145, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <40°F
  • Self-contained refrigeration system
  • Compressor: 1/3 H.P.
  • Refrigerant: R134a CFC-free
  • BTU: 2,600 per hour average
  • Electrical: 120 VAC
  • Minimum amps: 15
  • Cold carbonation technology
  • Carbonator: 1.67 GPM (100 GPH)
  • Water Bath: 6 Gallons
  • Ice Bank: 25 lbs
  • Weight: 165 lbs
  • Built-in re-circulatory pump allows for an installation distance up to 45’ between tower and chiller
  • 20”W x 20”D x 20”H

 Spec Sheet (774 KB)

CBDS-UCM2-2CL-S0096

Remote Beverage Chiller

Fountain Dispense Cold Carb Chiller

  • Remote recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser(s)
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean stainless steel cabinet
  • 304 stainless steel brushed finish panels
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 3, 12 oz drinks per minute (Max capacity: 145, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <40°F
  • Self-contained refrigeration system
  • Compressor: 1/3 H.P.
  • Refrigerant: R134a CFC-free
  • BTU: 2,600 per hour average
  • Electrical: 120 VAC
  • Minimum amps: 20.9
  • Cold carbonation technology
  • Carbonator: 1.67 GPM (100 GPH)
  • Water Bath: 6 Gallons
  • Ice Bank: 25 lbs
  • Dry Weight: 170 lbs
  • Built-in re-circulatory pump allows for aninstallation distance up to 75’ between tower and chiller
  • 20”W x 26”D x 20”H

Spec Sheet (764 KB)

NON-CARB CHILLERS

CBDS-P2000-SW

Undercounter Beverage Chiller

Fountain Dispense Non-Carb Chiller

  • Undercounter recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean, stainless steel cabinet
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 1, 12 oz drink per minute (Max capacity: 50, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <45°F
  • Self-contained refrigeration system
  • Compressor: 1/9 H.P.
  • Refrigerant: R134a CFC-free
  • Electrical: 120 VAC
  • Minimum amps: 3.3
  • Water Bath: 2.5 Gallons
  • Ice Bank: 6 lbs
  • Dry Weight: 80 lbs
  • 11.75”W x 17.5”D x 16.5”H

 Spec Sheet (620 KB)

CBDS-UCW

Remote Beverage Chiller

Fountain Dispense Non-Carb Chiller

  • Remote recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean, stainless steel cabinet
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 1.5, 12 oz drinks per minute (Max capacity: 80, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <45°F
  • Self-contained refrigeration system
  • Compressor: 1/5 H.P.
  • Refrigerant: R134a CFC-free
  • BTU: 2,2000 per hour average
  • Electrical: 120 VAC
  • Minimum amps: 2.9
  • Water Bath: 4 Gallons
  • Ice Bank: 17 lbs
  • Weight: 105 lbs
  • Built-in re-circulatory pump allows for an installation distance up to 35’ between chiller and dispenser
  • 12”W x 18.75”D x 24.5”H

Spec Sheet (638 KB)

CBDS-UCM2-SW-2CL

Remote Beverage Chiller

Fountain Dispense Non-Carb Chiller

  • Remote recirculation system keeps water and syrup chilled from the chiller to the beverage dispenser(s)
  • Reduced ice consumption compared to cold plate systems
  • Durable, easy to clean stainless steel cabinet
  • Reduced counter space need compared to cold plate systems

Specifications

  • Dispense capacity: 3, 12 oz drinks per minute (Max capacity: 145, 12 oz drinks at this duty cycle)
  • Flow rate: 3 oz per second
  • Dispense temperature: <45°F
  • Self-contained refrigeration system
  • Compressor: 1/3 H.P.
  • Refrigerant: R134a CFC-free
  • BTU: 2,400 per hour average
  • Electrical: 120 VAC
  • Minimum amps: 7.7
  • Water Bath: 6 Gallons
  • Ice Bank: 25 lbs
  • Weight: 135 lbs
  • Built-in re-circulatory pump allows for an installation distance up to 45’ between tower and chiller
  • 20”W x 20”D x 20”H

Spec Sheet (695 KB)